Generator repair
Repair of an electronically regulated generator with super magnets
Online since: 21/07/2009,
Number of visits: 429674
0
Here is a short documentation for the repair of an electronically regulated permanent field generator with super magnets.
Due to a loose screw on the motor shaft the magnetic disk was destroyed.
I arranged for clean adherends and glued 12 Q-19-13-06-N
into the disk.
Since the field force of supermagnete was incomparably higher, I decided to insert only every other magnet, of course with the correct polarity and number of pole pairs.
The existing PVC spacer ensured the proper distribution.
The new air gap between rotor and static coils was larger now, but that didn't influence the functioning.
The repair with super magnets was extremely successful.
The revolutions per minute (rpm) of the electronically regulated four cycle engine was lower than before the generator broke down.
Its noise emission is lower.
The low working rpm range is still enough and the motor will not be "tortured", despite the now smaller centrifugal mass and the larger field force of the magnetic rotor.
My decision to not implant all super magnets was apparently the right one!
The entire content of this site is protected by copyright.
Copying the content or using it elsewhere is not permitted without explicit approval.
Copying the content or using it elsewhere is not permitted without explicit approval.